Electronic Bulk Density Porosity Water And Absorption Tester For Ceramic
Standard specification:
According to GB/T2413, 1966, 2834, ASTM C20/C134/C373/C329, EN-725, it can be applied to the boiling method, vacuum saturation method, and wax sealing method measurement. According to the principle of Archimedes buoyancy, fast fead the measured value.
Application
Test the density, water absorption and porosity of porous ceramics, dense ceramics, alumina, zirconia, powder, etc.
MZ-C300/C600 Accuracy:0.001g/cm³ | MZ-C150 (Equipped with wind and dust cover) Accuracy:0.0001g/cm³ |
Patented product: Intelligent MAY-ENTRIS120 series Accuracy:0.0001g/cm³ It can measure 10 sets of samples at a time | MZ-C3000 (Size can be customized as required) Accuracy: 0.001g/cm³ |
Features
1. Digital display direct reading, without manual calculation, direct display of density and volume.
2. Porous ceramics, dense ceramics, powders and other similar products can be quickly measured.
3. The German original HBM sensor is used for accurate measurement, easy operation, stable and durable.
4. It has the function of actual water temperature compensation, which can adapt to changes in the test environment.
5. The density of the medium can be set, water is used as the medium, and other liquid mediums can also be used.
6. Adopting one-piece high-capacity measuring platform, corrosion-resistant and drop-proof, free replacement for life.
7. Mayzun-Smart multi-sample measurement system is optional, which can measure 10 sets of data at a time to achieve high-efficiency measurement. One-key printing of A4 standard data reports can store more than 100,000 sets of data.
8. Equipped with a special wind-proof and dust-proof cover, which is easy to combine and durable.
9. With RS-232C communication interface, it is convenient to connect PC and printer. MZ-P1 printer can be selected to print measurement data
MZ-C150 function description
Function 1: For ceramic products with pores and water absorption, it can directly read volume density (media method), apparent density, wet density, apparent porosity, water absorption, open pore volume, closed pore volume, and total porosity.
Function 2: For ceramic products with pores and water absorption, the volume density can be directly read (sealing wax method).
Function 3: For non-porous and non-absorbent ceramic products, the density of the product can be directly read
Function 4: For powder samples, a dedicated pycnometer can be configured to directly read the true density of the powder.
MZ-C300/C600/C3000 function description
Function 1: For ceramic products with pores and water absorption, the volume density (media method), volume density (sealing wax method), apparent density, wet density, apparent porosity, and water absorption can be directly read.
Function 2: For ceramic products that do not absorb water, the density of the product can be directly read.
Function 3: For powder samples, a dedicated pycnometer can be configured to directly read the true density of the powder.
Technical parameters
(Note: A large range of large-scale density meters can be customized according to customer needs, and the maximum can be customized 6-30kg)
Brand | MAYZUM ( Warranty period: three years) | |||
Model | MZ-C300 | MZ-C600 | MZ-C150 | Intelligent MAY-ENTRIS120 |
Max load | 0.005-300g | 0.01-600g | 0.002-150g | 0.0001-120g |
Measuring efficiency | Only one set of samples can be tested at a time | Only ten sets of samples can be tested at a time | ||
Density accuracy | 0.001 g/cm3 | 0.0002 g/cm3 | 0.0001 g/cm3 | |
Density range | 0.001~99.999g/cm3 | |||
Water absorption | Water absorption, porosity 0.01% | |||
Measurement type | Porous ceramics, dense ceramics, powders and other similar products | |||
Measuring principle | Archimedes drainage method principle | |||
Reading response time | About 2 seconds | |||
Measurement procedure | 1. Put it on the measuring table and press the save button to remember; 2. Put the hanging basket in the water and press the save button to display the density and volume directly The test procedure of porous materials is based on the national standard, please refer to the random manual | |||
The display results | Bulk density (media method), apparent density, wet density, apparent porosity, water absorption, open pore volume, closed pore volume, total porosity; true density of powder. | |||
Parameter setting | Water temperature setting, medium liquid density setting | |||
Correction method | One-key automatic correction | |||
Output method | RS-232C standard communication interface, convenient for test data output and printing | |||
Temperature and humidity range | Allowable ambient temperature: 0~45℃; Allowable relative humidity: within 80% | |||
Power supply | AC~220V / 50HZ | |||
Operation panel | Japan Omron mechanical keys | |||
Standard accessories | ①Host computer, ②Sink, ③Measuring table, ④Tweezers, ⑤Bubble dropper, ⑥Weight, ⑦Power transformer, ⑧Particle measuring accessories, ⑨Floating material measuring accessories | |||
Optional accessories | MZ-P1 printer MAYZUM-Smart multi-sample measurement system | |||
Other parameters | Outer packing size: 395*195*330mm; Body size: 210*195*185mm Net weight of the whole machine: 3.5kg; Gross weight: 4.5kg HS code: 90160090) |
Intelligent MAY-ENTRIS120 (Equipped with May-D70 data processor) measuring system preview
A4 report is automatically generated after the measurement is completed: