织梦dedecms大气智能环保设备类网站模板(带手机端)-跟版网
Location: Home  > Products  > Liquid Densimeter  > Desktop Baume Tester  > MAY-G300-BE Intelligent Liquid Baume Tester

MAY-G300-BE Intelligent Liquid Baume Tester

MAY-G300-BE Intelligent Liquid Baume Tester

Product introduction:


According to: GB/T13531, T5526, T5009, ASTM, JIS, ISO specifications. Apply Archimedes' principle of buoyancy method to quickly read the relative density and concentration of liquids.

Concentration coefficient: refers to the coefficient of relative density conversion to concentration. The relative density and concentration of a liquid cannot present an absolute linear relationship, but a certain curve relationship. This equipment uses

The unique 4-point curve algorithm converts the relative density and concentration of various liquids. The 4-point curve algorithm has higher accuracy than the 2-point linear algorithm. At different temperatures, the relative density conversion coefficient of the same liquid is not Similarly, this device has built-in more than 100 groups of liquid (ethanol, methanol, sodium hydroxide, sulfuric acid, nitric acid, etc.) concentration conversion coefficients at different temperatures.





Digital display direct reading parameters:

Relative density 

Specific gravity 

Concentration 

Baume degree 

Brix

Alcohol degree 

Water glass modulus




Application:

Chemical solution, alcohol, oil, water glass, any other fluid liquid




Technical Parameters:

Model

MAY-G150

MAY-G300

Weighing range

0.001~150g

0.01~300g

Density/specific gravity accuracy

0.0001g/cm³

0.001g/cm³

Concentration accuracy

0.01% (Accuracy can be set by the user)

Density/concentration resolution range

0.001~99.999g/cm³ / 0.01%~100%

Concentration parameter setting method

Built-in more than 100 groups of sample concentration parameters, one-key switching on the touch screen



Features:


1. Touch control operation, one-key selection of liquid concentration coefficient, eliminating tedious setting steps;

2. Use a unique multi-point curve concentration measurement algorithm to test the concentration of various chemical liquids (such as alcohol, methanol, sodium hydroxide, sulfuric acid, etc.). Compared with the common two-point linear concentration measurement algorithm on the market, it has more points The curve concentration measurement algorithm has higher accuracy;

3. Built-in temperature setting compensation function, which can quickly set the temperature value of the liquid to be measured, and can also be equipped with thermostatic equipment to measure the density/concentration value of the liquid at a specific temperature (such as 25°C);

4. This instrument adopts microcomputer touch screen operation, all Chinese parameter settings, the operation is clear at a glance; and each operation step is reversible (for example: if there is a problem with the operation step, you can return to the step to operate again, without starting from the beginning) ;

5. Support user personalized function customization.

  


Recommended